Main Subjects = Physics of Radiotherapy
Validation of Motorized Wedge Effective Isodose Angle with a 2D Array Detector

Volume 17, Issue 6, November and December 2020, Pages 380-385

10.22038/ijmp.2019.38832.1508

Jaimin Samabhai Gamit; shreekripa Rao; Jyothi Nagesh; Sarath S.Nair; Shambhavi Charan; Rechal Nisha Dsouza; Krishan Sharan; Srinidhi Chandraguthi


Impact of Multi-criteria Optimization on 6-MV Flattening Filter-Free Volumetric Modulated Arc Therapy for Craniospinal Irradiation

Volume 17, Issue 6, November and December 2020, Pages 386-393

10.22038/ijmp.2019.43270.1655

Mohandass P; KHANNA D; Selvaganapathi A; Nishaanth B; Saravanan C; Thiyagaraj T; Narendra Kumar Bhalla; a Puri; Blessy M


Boron Neutron Capture Therapy for Breast Cancer during Pregnancy: A Feasibility Study

Volume 17, Issue 6, November and December 2020, Pages 401-409

10.22038/ijmp.2019.42755.1639

Yasaman Rezaei Moghaddam; Laleh Rafat Motavalli; Seyed Hashem Miri-Hakimabad; Elie Hoseinian-Azghadi


Validation of Monte Carlo Model for Dose Evaluation outside the Treatment Field for Siemens 6MV Beam

Volume 17, Issue 6, November and December 2020, Pages 410-420

10.22038/ijmp.2019.42881.1646

Sinousy Dina Mohamed Sinousy; Attalla Ehab Marouf Attalla; Ibrahim Hassan Fathy; Elhussiny F. Fathi Ahmed; Elmekawy Ahmed Farouk


Evaluation of Six-Dimensional Cranial Target Positioning Accuracy in Two Different Immobilization Methods Using Exactrac System

Volume 17, Issue 5, September and October 2020, Pages 308-315

10.22038/ijmp.2019.35652.1448

Tamil Selvan Kasirajan; Padma Ganesan; Revathy Murugesan Kesavan; Arunai Nambi Raj N; Senthilnathan K; Ramesh Babu P


Quality Assurance of LINAC by Analyzing the Profile of 6-MV and 10-MV Photon Beams Using Star Track Device

Volume 17, Issue 4, July and August 2020, Pages 260-265

10.22038/ijmp.2019.39987.1543

Basma Sabur Lazim; Basim Khalaf Rejah; Haydar H. Alabedi


Introduction of a Reliable Software for the Calculation of the Gamma Index

Volume 17, Issue 3, May and June 2020, Pages 133-136

10.22038/ijmp.2019.39178.1557

Sanaz Hariri Tabrizi; Nematollah Heidarloo; Mina Tavallaie


Fabrication and Characterization of Bolus Material Using Propylene Glycol for Radiation Therapy

Volume 17, Issue 3, May and June 2020, Pages 161-169

10.22038/ijmp.2019.39798.1537

Aditya Prayugo Hariyanto; Fachrina Mariyam; Levina Almira; Endarko Endarko; Bambang S


Effect of Dental Filling Materials on Electron Beam Radiotherapy Dose Distribution in Head Region: a Monte Carlo Study by FLUKA and MCNPX Codes

Volume 17, Issue 3, May and June 2020, Pages 183-187

10.22038/ijmp.2019.36221.1460

Mohamad Reza Rezaie Rayeni Nejad; Reza shahhedarypoor; saeed mohammadi; parviz parvaresh


Characterization of Wedge Factors and Dose Distributions in Radiotherapy with Symmetric and Asymmetric Physical Wedged Beams of 6 MV Photon Beam

Volume 17, Issue 3, May and June 2020, Pages 213-219

10.22038/ijmp.2019.41275.1595

mansour zabihzadeh; Mahbube Fadaei; Seyed Mohammad Hoseini; Sholeh Arvandi; Mohamad Tahmasebi


Assessment of Different Training Methods in an Artificial Neural Network to Calculate 2D Dose Distribution in Radiotherapy

Volume 17, Issue 2, March and April 2020, Pages 114-119

10.22038/ijmp.2019.39429.1522

Mahdi Saeedi-Moghadam; Kamal Hadad; Banafsheh Zeinali-Rafsanjani; Reza Jalli


Dosimetric Study of an Indigenous and Heterogeneous Pelvic Phantom for Radiotherapy Quality Assurance

Volume 17, Issue 2, March and April 2020, Pages 120-125

10.22038/ijmp.2019.39332.1520

Sudha Singh; payal raina; Om Prakash Gurjar


Investigation of Neutron Contamination of Flattening Filter and Flattening Filter-Free 10-MV Photon Beams in Elekta InfinityTM Accelerator

Volume 17, Issue 2, March and April 2020, Pages 126-132

10.22038/ijmp.2019.37195.1471

Sitti Yani; Indra Budiansah; Fauzia Puspa Lestari; Mohamad Rhani; Rasito Tursinah; Freddy Haryanto


Analysis of the Attenuation Coefficient of Composite Silicone Rubber and Gliceryn for Soft Tissue Phantom Applications

Volume 17, Issue 1, January and February 2020, Pages 1-6

10.22038/ijmp.2019.38410.1494

Asnaeni Ansar; Dahlang Tahir; Bualkar Abdullah; . Nurhasmi; . Jusmawang; Satrial Male; Ruth Meisye Kaloari


Investigation of LINAC Structural Effects on Photoneutron Specified Parameters Using FLUKA code

Volume 17, Issue 1, January and February 2020, Pages 7-14

10.22038/ijmp.2019.37678.1481

Mohammad Ashrafinia; Asghar Hadadi; Dariush Sardari; Elham Saeedzadeh


Dosimetric Characteristics of Transparent Bolus for External Beam Radiotherapy

Volume 16, Issue 6, November and December 2019, Pages 410-415

10.22038/ijmp.2019.37129.1470

Kesavan Govindaraj; SenthilKumar S; Jeevan Ram R.K


In Vivo Dosimetry Using a Flat Surface Sun Nuclear Corporation Diode in 60co Beams for Some Radiotherapy Treatments in Ghana

Volume 16, Issue 5, September and October 2019, Pages 329-335

10.22038/ijmp.2018.29705.1324

Vivian Della Atuwo‑Ampoh; Eric Naab Manson; Cyril Schandorf; Samuel Nii Tagoe; Eric K.T Addison; Emmanuel Fiagbedzi


New Method of Quality Control Test for Light and Radiation Field Coincidence in Medical Linear Accelerators

Volume 16, Issue 5, September and October 2019, Pages 336-340

10.22038/ijmp.2019.21250.1202

Mahdi Heravian Shandiz; Mohammad-Hossein Bahreyni-Toosi; Ghorban Safaeian Layen; Amir Hossein Ziaei