ORIGINAL_ARTICLE
Stereotactic Radiosurgery/Radiotherapy: A Historical Review
"Stereotactic" is an exact radiotherapy treatment modality which implements invasive and non-invasive facilities for improving precise dose delivery. Stereotactic refers to three-dimensional localization of a specific point in space by a unique set of coordinates that relate to a fixed external reference frame. An accurate delivery of radiation is attainable using these techniques with high precision (1-2 mm) which leads to dose reduction in critical organs and adjacent normal tissues while delivering the highest dose to tumoral tissue. Stereotactic irradiation consists of two techniques of delivery: Stereotactic RadioSurgery (SRS) which is an accurate single fractionated delivery of radiation to intracranial lesions and is attained by converging series of radiation beams on a target from various angles. Stereotactic Radiotherapy (SRT) which is a fractionated irradiation of intra and extra cranial lesions. This review article intends to highlight the radiobiological and physical aspects of these techniques and also introduces three commercially available stereotactic machines systematically and functionally.
https://ijmp.mums.ac.ir/article_2621_8411707e06edf38cdf6ff5830d504f48.pdf
2014-03-01
156
167
10.22038/ijmp.2014.2621
Equipments
Stereotactic radiosurgery
stereotactic radiotherapy
Mansoureh
Nabavi
m-nabavi@farabi.tums.ac.ir
1
1- Department of Engineering, Science and Research Branch, Islamic Azad University, Tehran, Iran
2- Radiotherapy Oncology Department, Cancer Research Centre, Cancer Institute, Tehran University of Medical Sciences, Tehran, Iran
AUTHOR
Hassan Ali
Nedaie
nedaieha@sina.tums.ac.ir
2
2- Radiotherapy Oncology Department, Cancer Research Centre, Cancer Institute, Tehran University of Medical Sciences, Tehran, Iran
LEAD_AUTHOR
Narges
Salehi
n.sli.sis@gmail.com
3
Department of Medical Engineering, Tehran University of Medical Sciences, Tehran, Iran
AUTHOR
Mansour
Naderi
4
Radiotherapy Oncology Department, Cancer Research Centre, Cancer Institute, Tehran University of Medical Sciences, Tehran, Iran
AUTHOR
ORIGINAL_ARTICLE
Assessment of Outdoor Gamma Radiation Dose Rates in 49 Cities of Guilan Province, IRAN
Introduction Guilan is one of the provinces in North of Iran, with population of 2,480,874 and a total area of 14,042 square kilometers. This study assesses the outdoor natural gamma dose rates in the air of 49 cities in Guilan and calculates corresponding average annual effective dose. Materials and Methods A total of 260 different sample points measurements were carried out. The results include both terrestrial and cosmic ray components of gamma radiation level. Results The outdoor gamma dose rates range from 65 to 127 nSv h-1 with the mean of 94 ± 24 nSv h-1. Conclusion The average outdoor gamma dose rate for Guilan determined in this study is significantly higher in comparison with values reported by UNSCEAR 2000 from different countries with the mean of 59 nSv although in comparison with many provinces of Iran, it is lower.
https://ijmp.mums.ac.ir/article_2622_5b22e391e35a6b7a9b8be1b3eb03af5f.pdf
2014-03-01
168
174
10.22038/ijmp.2014.2622
Background Radiation
Guilan
Iran
Outdoor Dose Rate
Sedigheh
Basirjafari
1
Student of Medicine, Faculty of Medicine, Guilan University of Medical Sciences, Rasht, Iran
AUTHOR
Saeideh
Aghayari
2
Student of Medicine, Faculty of Medicine, Guilan University of Medical Sciences, Rasht, Iran
AUTHOR
Seyed Mohammad
Poorabas
3
Student of Medicine, Faculty of Medicine, Guilan University of Medical Sciences, Rasht, Iran
AUTHOR
Hassan
Moladoust
hmoladoust@gums.ac.ir
4
Biochemistry & Biophysics Dept., Faculty of Medicine, Guilan University of Medical Sciences, Rasht, Iran
AUTHOR
Mohsen
Asadinezhad
asadinejad_m@yahoo.com
5
Biochemistry & Biophysics Dept., Faculty of Medicine, Guilan University of Medical Sciences, Rasht, Iran
LEAD_AUTHOR
ORIGINAL_ARTICLE
Silastic Thickness Optimization in Uveal Melanoma Brachytherapy by Monte Carlo Method
Introduction In order to treat uveal Melanoma , first, radioactive seeds are laid on a silicone- made substance which is called Silastic after that they are inserted in the plaque, and finally, this plaque containing silicone-made substance is stitched to the sclera surface. The dose gradient within the tumor and healthy tissues can be varied due to changing the Silastic thickness between sclera surface and radioactive seeds. In turn, this leads to difference in the amount of absorbed dose of tumor and healthy tissues. Present study is to investigate the optimum Silastic thickness in uveal Melanoma brachytherapy. Materials and Methods To measure changes of depth dose of the plaque in a sphere with a radius of 12 mm, MCNP4C code was applied. Exact specifications of a 20-mm Collaborative Ocular Melanoma Study (COMS) plaque, Silastic and three I-125 seed sources, 6711 model were integrated in simulation. Dose calculations were performed using F6 tally in spheres with a radius of 0.2 mm. Results By measuring the changes of dose rate of plaque in distances of 0.2 to 18 mm from the sclera surface and having the prescribed dose for the absolute treatment of eye melanoma, final absorbed doses by tumor and healthy tissues for each different Silastic thicknesses of 0, 0.5, 1, 1.5, and 2 were calculated. Conclusion Considering the results and sclera tolerance, it was concluded that the thickness of Silastic must not exceed 0.5 mm, because increasing the Silastic thickness from this area, increases absorbed dose by healthy tissues and also the treatment time.
https://ijmp.mums.ac.ir/article_2624_353267d0fde7df5cda8a87e020792667.pdf
2014-03-01
175
181
10.22038/ijmp.2014.2624
Uveal Melanoma
I-125 Source
Monte Carlo
Silastic
Ramezan
Eidi
r.eidi64@gmail.com
1
Radiation Medicine Department, Shahid Beheshti University, Tehran, Iran
LEAD_AUTHOR
Seyed Mahmoudreza
Aghamiri
2
Department of Nuclear Research Center, Atomic Energy Organization of Iran, Tehran, Iran
AUTHOR
Shahab
Sheibani
3
Department of Nuclear Research Center, Atomic Energy Organization of Iran, Tehran, Iran
AUTHOR
Ramin
Jaberi
4
Imam Khomeini Hospital, Tehran University of Medical Science, Tehran, Iran
AUTHOR
Hossein
Pourbeigi
5
Department of Nuclear Research Center, Atomic Energy Organization of Iran, Tehran, Iran
AUTHOR
Mohsen
Mashayekhi Galatoiyeh
6
Physics Department, Hakim Sabzevari University, Sabzevar, Iran
AUTHOR
Seyed Mohsen
Hosseini Daghigh
7
Radiation Medicine Department, Shahid Beheshti University, Tehran, Iran
AUTHOR
ORIGINAL_ARTICLE
Quality Control Status of Radiology Centers of Hospitals Associated with Mashhad University of Medical Sciences
Introduction Using ionization radiation for diagnostic and treatment fields has increased worldwide dramatically. This issue causes an increase in the absorbed and collective doses in society noticeably. With regard to two main principles in radiation protection, i.e., justification and optimization, it is necessary to have imaging process with minimum dose to patients and personnel. For achieving this, it is vital to perform quality control tests regularly. On this topic, many studies have been performed and reported worldwide which show necessities and meaningfulness of QC tests. Materials and Methods In this study, Unfors Mult-O-Meter model 303 is used for surveying accuracy of kVp and time, linearity of exposure with mAs, and reproducibility of exposure. Results According to recommendations of AAPM (2002) and ICRP 103, in this study, 27% of apparatuses in accuracy of kVp, 45% in accuracy of timer, and 30% in accuracy of reproducibility were out of accepted range. Conclusion In surveyed apparatuses, both ends of operating range have large errors in therefore it is recommended that these devices should not be used in the mentioned regions. Performing strict quality control on all radioactive devices is one of the radiation protection priorities that should be done periodically .With regard to the results, repair, substitution or omition of some devices are suggested.
https://ijmp.mums.ac.ir/article_2625_4c0b20e00d0dbe21d64863b06388e480.pdf
2014-03-01
182
187
10.22038/ijmp.2014.2625
Mult-O-Meter, Quality Control
Radiography
Reproducibility of Results
Hamid
Gholamhosseinian-Najjar
1
Department of Medical Physics, Faculty of Medicine, Mashhad University of Medical Sciences, Mashhad, Iran
AUTHOR
Mohammad-Taghi
Bahreyni-Toosi
2
Department of Medical Physics, Faculty of Medicine, Mashhad University of Medical Sciences, Mashhad, Iran
AUTHOR
Mohammad-Hossein
Zare
zaremh871@mums.ac.ir
3
Department of Medical Physics, Faculty of Medicine, Mashhad University of Medical Sciences, Mashhad, Iran
LEAD_AUTHOR
Hamid-Reza
Sadeghi
4
Department of Medical Physics, Faculty of Medicine, Mashhad University of Medical Sciences, Mashhad, Iran
AUTHOR
Hamid-Reza
Sadoughi
hr.sadoughi@mums.ac.ir
5
Department of Medical Physics, Faculty of Medicine, Mashhad University of Medical Sciences, Mashhad, Iran
AUTHOR
ORIGINAL_ARTICLE
Optical Characterization of NIPAM and PAGAT Polymer Gels for Radiation Dosimetry
Introduction The purpose of the current study was to determine optical sensitivity of N-isopropyl acrylamide NIPAM and polyacrylamide gelatin and tetrakis hydroxymethyl phosphoniun chloride (PAGAT) polymer gels for different wavelength of visible light spectrum applied in optical computed tomography method. Materials and Methods NIPAM and PAGAT polymer gels with conventional formulations used for polymer gel dosimetry in radiation therapy were prepared. Using a laboratory spectrophotometer, light absorbance against wavelength of light spectrum from 400 to 700 nm was measured. The optical absorbance-dose response curves were obtained for different wavelengths and the results were compared to find the wavelength where the highest sensitivity of polymer gels is occurred. Results The results showed light wavelength dependency for polymer gels optical absorbance-dose sensitivity. The highest sensitivity was seen in the blue part of visible light at wavelengths of 440 and 460 nm for PAGAT and NIPAM, respectively. Moreover, the sensitivity of NIPAM gel was higher than PAGAT for all studied wavelengths. Conclusion The sensitivity of both gels varied considerably with light wavelength and was higher in shorter wavelength of visible light. It is recommended to study optical absorbance-dose sensitivity of polymer gels for selecting the optimum light wavelength for optical measurements and optical computed tomography applications.
https://ijmp.mums.ac.ir/article_2626_b8b82d9064ef27d2165312a32d0430e2.pdf
2014-03-01
188
194
10.22038/ijmp.2014.2626
Gel Dosimetry
NIPAM polymer
Optical Response
PAGAT polymer
Asghar
Mesbahi
amesbahi2010@gmail.com.
1
Medical Physics Department, Faculty of Medicine, Tabriz University of Medical Sciences, Tabriz, Iran.
Radiation Oncology Department, Imam Hospital, Tabriz, Iran
LEAD_AUTHOR
Seyed-Salman
Zakariaee
2
Medical Physics Department, Faculty of Medicine, Tabriz University of Medical Sciences, Tabriz, Iran.
AUTHOR
ORIGINAL_ARTICLE
Electron Beam Dose Distribution in the Presence of Non-Uniform Magnetic Field
Introduction Magnetic fields are capable of altering the trajectory of electron beams andcan be used in radiation therapy.Theaim of this study was to produce regions with dose enhancement and reduction in the medium. Materials and Methods The NdFeB permanent magnets were arranged on the electron applicator in several configurations. Then, after the passage of the electron beams (9 and 15 MeV Varian 2100C/D) through the non-uniform magnetic field, the Percentage Depth Dose(PDDs) on central axis and dose profiles in three depths for each energy were measured in a 3D water phantom. Results For all magnet arrangements and for two different energies, the surface dose increment and shift in depth of maximum dose (dmax) were observed. In addition, the pattern of dose distribution in buildup region was changed. Measurement of dose profile showed dose localization and spreading in some other regions. Conclusion The results of this study confirms that using magnetic field can alter the dose deposition patterns and as a result can produce dose enhancement as well as dose reduction in the medium using high-energy electron beams. These effects provide dose distribution with arbitrary shapes for use in radiation therapy.
https://ijmp.mums.ac.ir/article_2630_2cbce93288e60a364b15d48ff9bf26ef.pdf
2014-03-01
195
204
10.22038/ijmp.2014.2630
Electron Beam
Magnetic Field
Radiation Therapy
Mohamad Javad
Tahmasebi-Birgani
mjtmsebi@yahoo.com
1
Department of Medical Physics, JundishapurUniversity of Medical Sciences, Ahvaz, Iran
AUTHOR
Mohamad Reza
Bayatiani
bayatiani@yahoo.com
2
Radiotherapy and Medical Physics Department of Arak University of Medical Sciences&Khansari Hospital, Arak, Iran
LEAD_AUTHOR
Fatemeh
Seif
sahar_s59@yahoo.com
3
Radiotherapy and Medical Physics Department of Arak University of Medical Sciences&Khansari Hospital, Arak, Iran
AUTHOR
Mansur
Zabihzadeh
manzabih@gmail.com
4
Department of Medical Physics, JundishapurUniversity of Medical Sciences, Ahvaz, Iran
AUTHOR
Hojatolah
Shahbazian
shabazian@yahoo.com
5
Department of Medical Physics, JundishapurUniversity of Medical Sciences, Ahvaz, Iran
AUTHOR
ORIGINAL_ARTICLE
Dose Assessment of Eye and Its Components in Proton Therapy by Monte Carlo Method
Introduction Proton therapy is used to treat malignant tumors such as melanoma inside the eye. Proton particles are adjusted according to various parameters such as tumor size and position and patient’s distance from the proton source. The purpose of this study was to assess absorbed doses in eyes and various tumors found in the area of sclera and choroid and the adjacent tissues in radiotherapy while changing most important proton therapy parameters such as moderators thickness (1.5-1.9 cm), exposure radius (0.5-0.8 cm), and proton energy beam (53.5-65 MeV). Materials and Methods A proton therapy system of Laboratori Nazionali del Sud-INFNwas simulated by Monte Carlo method. Moreover, the eye and its components were simulated using concentric spheres. To obtain a more accurate results, real density of eye components such as cornea and lens, were applied for simulation. Then, the absorbed dose of eye and eye tumor, in choroid and sclera areas, were calculated by Monte Carlo method. Results The absorbed dose in tumoral region of eye was calculated to be about 12.5 ±0.006Gy in one day with energy 62 MeV for a therapy session, which is suitable for treatment. However, normal eye cells received at most 11.01 Gy which is high. Conclusion The amount of absorbed dose in tumoral cells is noticeable. Therefore, accurate treatment planning, patient immobility and fine calibration of proton-therapy system and its simulator are very important to reduce the absorbed dose of healthy cells.
https://ijmp.mums.ac.ir/article_2631_ea82c340578ad3d8443bfaa12563ba2d.pdf
2014-03-01
205
214
10.22038/ijmp.2014.2631
Absorbed Dose
Melanoma
Monte Carlo Method
Proton Therapy
Marzieh
Tavakol
1
Department of Physics, Faculty of Science, University of Isfahan, Isfahan, Iran.
AUTHOR
Alireza
Karimian
karimian@eng.ui.ac.ir
2
Department of Biomedical Engineering, Faculty of Engineering, University of Isfahan, Isfahan, Iran.
LEAD_AUTHOR
Sayyed Mojtaba
Mostajab Aldaavati
3
Department of Physics, Faculty of Science, University of Isfahan, Isfahan, Iran
AUTHOR
ORIGINAL_ARTICLE
Designing and Constructing an Optical System to measure Continuous and Cuffless Blood Pressure Using Two Pulse Signals
Introduction Blood pressure (BP) is one of the important vital signs that need to be monitored for personal healthcare. Arterial blood pressure is estimated from pulse transit time (PTT). This study uses two pulse sensors to get PTT. The aim of this study was to construct an optical system and to monitor blood pressure continuously and without cuff in people with different ages. Materials and Methods To measure blood pressure changes, two infrared optical transmitters were used at the distances of 5 mm to the receivers. Output of the optical receivers was inserted in analog circuits. PTT was defined as the time between the two peaks of pulse signals by the software. Signals were measured continuously through a serial network communication. An external personal computer monitored measured waveforms in real time. BP was related to PTT and the relationship coefficients were calculated at different physical activities. After determining the linear correlation coefficients for each individual, blood pressure was measured by the cuff and the PTT method and the results were compared. Results PTT computed between the two peaks of wave pulses was strongly correlated with systolic blood pressure (R=0.88±0.034) and the diastolic blood pressure (R=0.82±0.058). Systolic blood pressure (SBP) was measured more accurately than the diastolic blood pressure (DBP). The results of SBP showed that the maximum difference and the error percentages between the cuff method and the present method were 7.98±2.88 and 6.33±2.51%, respectively. Moreover, the maximum difference and the percentage errors between the cuff method and the present method of DBP were 10.13±3.82 and 10.97±3.89%, respectively. Conclusion Monitoring blood pressure with the designed system can be recommended as a useful method to indicate cardiovascular diseases and used for personal healthcare purposes.
https://ijmp.mums.ac.ir/article_2632_eefd362826788210b6aea1631c37320b.pdf
2014-03-01
215
223
10.22038/ijmp.2014.2632
Blood Pressure Monitoring
Optical System
Pearson Correlation
Pulse Wave
Mohamad Amin
Younessi Heravi
a.younessi7@gmail.com
1
Department of Basic Sciences, North Khorasan University of Medical Sciences, Boujnurd, Iran.
LEAD_AUTHOR
Mohamad Ali
Khalilzadeh
2
Department of Biomedical Engineering, Islamic Azad University of Mashhad Branch, Mashhad, Iran
AUTHOR