TY - JOUR ID - 13020 TI - Evaluation putty metal as internal shield for patient protection of electron therapy by Monte Carlo study JO - Iranian Journal of Medical Physics JA - IJMP LA - en SN - AU - Tahmasebi Birgani, Mohammad javad AU - Zabihzadeh, Mansour AU - Aliakbari, Saeideh AU - Behrouz, Mohammad Ali AU - Hosseini, Seyyed Mohammad AD - Professor, Department of Medical Physics, School of Medicine; Department of Radiotherapy and Radiation Oncology, Golestan Hospital, Ahvaz Jundishapur University of Medical Sciences, Ahvaz,Iran,Tahmasebi_MJ@yahoo.com AD - Assistant professor, Department of Medical Physics, School of Medicine, Ahvaz Jundishapur University of Medical Sciences, Ahvaz,Iran, zabihzadeh@ajums.ac.ir AD - Ph. D Candidate , Department of Medical Physics, School of Medicine, Ahvaz Jundishapur University of Medical Sciences, Ahvaz,Iran, aliakbarisaeedeh@gmail.com AD - Professor, Department of Medical Physics, School of Medicine; Ahvaz Jundishapur University of Medical Sciences, Ahvaz,Iran, mabehrooz@yahoo.com AD - Assistant Professor, Department of Radiation Therapy, University of JundiShapoor, Golestan Hospital, Ahvaz, Iran, kiahossainy@yahoo.com Y1 - 2018 PY - 2018 VL - 15 IS - Special Issue-12th. Iranian Congress of Medical Physics SP - 356 EP - 356 KW - flexible internal shielding KW - Dose Enhancement KW - Electron- backscattering DO - 10.22038/ijmp.2018.13020 N2 - Introduction: In this study, a specific combination (70% W 18.61% Ni and 11.39% C) of lead free and flexible putty metal is introduced and validated as internal shielding by Mont Carlo study Materials and Methods: To evaluate putty metal as an internal shielding by Mont Carlo study Varian 2100 C/D was validated within measurement and then by given energy spectrum of Varian 2100 C/D shield thickness and backscatter factor were obtained by Mont Carlo study and compared to those of lead. Results: The results showed that this putty metal shield required comparable thickness for providing protection compared to lead. In addition, it is nontoxic and flexible in that it can be easily cut. Internal shielding with high atomic number causes dose enhancement that isn’t taken into account in treatment planning system. This study showed that this composition as internal shield causes 5-7% reduction of electron backscatter factor relative Lead. Conclusion: it can be concluded that lead can be replaced by putty metal with specific combination (70% W, 18.61% Ni and 11.39% C). It is Lead free, flexible and thickness required for protecting tissue is acceptable under clinical condition and it causes 5 -7% reduction of electron backscattering UR - https://ijmp.mums.ac.ir/article_13020.html L1 - ER -