TY - JOUR ID - 6835 TI - Medium-Term Stability of the Photon Beam Energy of An Elekta CompactTM Linear Accelerator Based on Daily Measurements of Beam Quality Factor JO - Iranian Journal of Medical Physics JA - IJMP LA - en SN - AU - Mosleh-Shirazi, Mohammad Amin AU - Rahimi, Saeed AU - Karbasi, Sareh AD - Physics Unit, Department of Radiotherapy and Oncology, Namazi Hospital, Shiraz University of Medical Sciences, Shiraz, Iran 2- Ionizing and Non-ionizing Radiation Protection Research Center, School of Paramedical Sciences, Shiraz University of Medical Sciences, Shiraz, Iran AD - Department of Medical Physics and Engineering, School of Medicine, Shiraz University of Medical Sciences, Shiraz, Iran Student Research Committee, Shiraz University of Medical Sciences, Shiraz, Iran AD - Physics Unit, Department of Radiotherapy and Oncology, Namazi Hospital, Shiraz University of Medical Sciences, Shiraz, Iran Y1 - 2015 PY - 2015 VL - 12 IS - 4 SP - 230 EP - 234 KW - Radiotherapy KW - Linear Accelerator KW - Quality Control KW - Photons KW - Beam KW - energy DO - 10.22038/ijmp.2016.6835 N2 - Introduction In this study, we aimed to assess the medium-term energy stability of a 6MV Elekta CompactTM linear accelerator. To the best of our knowledge, this is the first published article to evaluate this linear accelerator in terms of energy stability. As well as investigating the stability of the linear accelerator energy over a period of several weeks, the results will be useful for estimation of the required tolerance values for the beam quality factor (BQF) of the PTW QUICKCHECK weblineTM (QCW) daily checking device. Materials and Methods Over a 13 week period of routine clinical service, 52 daily readings of BQF were taken and then analyzed for a 10×10 cm2 field. Results No decreasing or increasing trend in BQF was observed over the study period. The mean BQF value was estimated at 5.4483 with a standard deviation (SD) of 0.0459 (0.8%). The mean value was only 0.1% different from the baseline value. Conclusion The results of this medium-term stability study of the Elekta Compact linear accelerator energy showed that 96.2% of the observed BQF values were within ±1.3% of the baseline value. This can be considered to be within the recommended tolerance for linear accelerator photon beam energy. If an approach of applying ±3 SD is taken, the tolerance level for BQF may be suggested to be set at ±2.5%. However, further research is required to establish a relationship between BQF value and the actual changes in beam energy and penetrative quality.  UR - https://ijmp.mums.ac.ir/article_6835.html L1 - https://ijmp.mums.ac.ir/article_6835_4b7b15ee54de46f3acddad280506bca3.pdf ER -