Main Subjects = Medical Physics
Radiation dose optimization during temporal bone CT examination using one-shot axial volumetric acquisition.

Articles in Press, Accepted Manuscript, Available Online from 24 July 2022

10.22038/ijmp.2022.63627.2087

Youssef Madkouri; Mohammed Aggour; Youssef Bouzekraoui; FARIDA BENTAYEB


Anatomical Information Quality Control of a Radiotherapy Treatment Planning System

Articles in Press, Accepted Manuscript, Available Online from 27 July 2022

10.22038/ijmp.2022.65094.2116

Rehab Abd Elaziz; Ibrahim awad; alia ahmed; Ahmed oraby


Blood of cancerous patients as biomarkers of alpha emitters

Articles in Press, Accepted Manuscript, Available Online from 10 August 2022

10.22038/ijmp.2022.64749.2111

Haura Mohammed Abas; SAHIB NEAMAH ABDUL-WAHID; Adie D. Salman Salman


Designed and validation of inhouse Head and Neck phantom for quality assurance and radiotherapy dose measurements

Articles in Press, Accepted Manuscript, Available Online from 18 September 2022

10.22038/ijmp.2022.63407.2084

mamta mahur; Munendra Singh; Om Prakash Gurjar; Manoj Kumar Semwal


Dosimetric comparison of fractionated stereotactic radiotherapy plans with and without flattening filter beams of 6MV and 10MV beams

Articles in Press, Accepted Manuscript, Available Online from 31 October 2022

10.22038/ijmp.2022.66949.2154

Hridya V T; KHANNA D; Aswathi Raj; Sathish Padmanabhan; Mohandass P


Design and development of an anthropomorphic heterogeneous female pelvic (AHFP) phantom for dosimetric verification of advance radiotherapy

Articles in Press, Accepted Manuscript, Available Online from 22 January 2023

10.22038/ijmp.2023.68397.2194

Neha Yadav; Manisha Singh; SURENDRA PRASAD MISHRA; MOHAMAD SHAHNAWAZ ANSARI; Atul Mishra


Simulation Study on the Effect of Multi-layer Biological Tissue on Focus Shift in High-Intensity Focused Ultrasound Therapy

Articles in Press, Accepted Manuscript, Available Online from 09 February 2023

10.22038/ijmp.2023.67536.2173

HU DONG; JIWEN HU; GAOFENG PENG; QI Chen; QIAOLAI TAN


Dosimetric validation of physical and biological indexes from the dose-volume histogram for evaluation of 3D-CRT and IMRT with VMAT treatment plan techniques in cervical tumors from in-house developed software

Articles in Press, Accepted Manuscript, Available Online from 13 February 2023

10.22038/ijmp.2023.67338.2168

Sougoumarane Dashnamoorthy; Ebenezar Jeyasingh; VINDHYAVASINI PRASAD PANDEY; Karthick Rajamanickam; Sachin S Kotur; Durga Prasad Sahoo


Predicting Mammographic Breast Density Assessment Using Artificial Neural Networks

Articles in Press, Accepted Manuscript, Available Online from 20 February 2023

10.22038/ijmp.2023.68587.2202

Soumaya Boujemaa; Youssef Bouzekraoui; FARIDA BENTAYEB


Analysis of dose-distribution in left-lung and heart as increasing the number of beams in left-sided breast irradiation

Articles in Press, Accepted Manuscript, Available Online from 10 March 2023

10.22038/ijmp.2023.62866.2071

Mohammad Shahanawaj Ansari; Mohammad Ziyauddin Khan; Sunil Dutt Sharma; Neha Yadav; Mukesh Kumar Zope


Analysis of Commissioning Parameters and its Validation of O-Ring Gantry Based Medical Linear Accelerator HalcyonTM for Improved Radiotherapy Technique

Articles in Press, Accepted Manuscript, Available Online from 13 March 2023

10.22038/ijmp.2023.69197.2215

ARVIND KUMAR; KIRAN SHARMA; CHANDI PRASAD BHATT; Suresh Yadav; SWATI VERMA; SOUGATA BASU; POOJA DHAUNDIYAL; DEEPAK KAUSHIK; DINESH Kumar SAROJ; Manoj Gupta


Performance of different Strength Aperture Shape Controller in Optimization with VMAT technique for Head and Neck, Pelvic and Breast Cancer using Halcyon Machine.

Articles in Press, Accepted Manuscript, Available Online from 12 April 2023

10.22038/ijmp.2023.68586.2201

Morad Erraoudi; Youssef Bouzekraoui; Mohammed Yassine Herrassi; Khalid Elouardi; Yassir Raoui; Mohamed El ghalmi; FARIDA BENTAYEB


Monitor Unit verification for irregular fields in radiotherapy based on Clarkson method combined with in-house MLC shaper software

Articles in Press, Accepted Manuscript, Available Online from 26 April 2023

10.22038/ijmp.2023.63585.2086

Athiyaman M; Hemalatha A; Mary Joan; ARUN CHOUGULE; kumar HS; Gokul Raj


Commentary on "The Feasibility of Hybrid IMRT treatment planning for Left sided Chest wall irradiation: A Comparative Treatment Planning Study"

Articles in Press, Accepted Manuscript, Available Online from 10 May 2023

10.22038/ijmp.2023.71982.2274

GAUTAM SARMA; Hrishikesh Kashyap; Partha Pratim Medhi


Influence of Segment Shape optimization parameter in radiotherapy Volumetric Modulated Arc Therapy planning of Cervical Cancer

Articles in Press, Accepted Manuscript, Available Online from 16 May 2023

10.22038/ijmp.2023.69271.2220

NIDHI JAIN; Alok Kumar; ASHOK KUMAR


ABSORBED DOSE MEASUREMENTS FOR TELETHERAPHY PREDICTION OF SUPERFICIAL DOSE USING HALCYON LINEAR ACCELERATOR

Articles in Press, Accepted Manuscript, Available Online from 20 June 2023

10.22038/ijmp.2023.64557.2107

RAYMOND LIMEN Njinga; Adeneye O Samuel; kinyode Ojumoola Ajimo; Christopher J Olowookere


Radioprotective effect of Ferula asafoetida oleo gum resin on ionizing radiation-induced oxidative stress and tissue damage in rats

Articles in Press, Accepted Manuscript, Available Online from 05 August 2023

10.22038/ijmp.2023.71276.2258

soheila safardoost; Shokouhozamanozaman Soleymanifard; vahidreza askari; Morteza Rezaei kahkha; Shirin Taraz Jamshidi; mahdi karimi; Hamid Gholamhosseinian


Over-response correction of SNC 350p Roos and PTW Markus chambers in surface dose and build up region dosimetry of 6MV photon beam

Articles in Press, Accepted Manuscript, Available Online from 11 August 2023

10.22038/ijmp.2023.71464.2264

Deepali Bhaskar Patil; Mukesh Kumar Zope; DINESH Kumar SAROJ; Aslam P. A.; Basil George


Evaluation of surface doses and effect of air gaps under bolus during external photon beam radiotherapy

Articles in Press, Accepted Manuscript, Available Online from 27 August 2023

10.22038/ijmp.2023.70746.2245

Papa Nii Odartey Lamptey; Edem Kwabla Sosu; George Felix Acquah; Cyril Schandorf


Combined Analysis of Breast Morphometry, Compression and Volumetric Breast Density: Valuable Input to Improve Mammography Screening Using International Bench Marking

Volume 20, Issue 3, May and June 2023, Pages 120-129

10.22038/ijmp.2022.59988.2008

Youssef Bouzekraoui; Hilde Bosmans; Lesley cockmartin; Mauro campoleoni; sanae Douama; imane Ou-saada; FARIDA BENTAYEB


Tissue Substitute Materials for the Human Colorectal Cancer Tissue

Volume 20, Issue 3, May and June 2023, Pages 136-145

10.22038/ijmp.2022.64221.2099

Emmanuel Okon Esien-umo; Joseph Abebe Obu; Ndubuisi Ozoemena Chiaghanam; Akwa Egom Erim; Nneoyi Onen Egbe