Main Subjects = Radiation Detection
Verification of the Accuracy of the Delivered Dose in Pelvic and Breast Cancer Radiotherapy by in-vivo Semi-Conductor Dosimetry

Volume 6, Issue 3,4, November and December 2009, Pages 38-45

Hamidreza Shabani; Mahmood Allahverdi; Mahbod Esfahani; Mehdi Aghili; Abbas Takavar; Mohammd Reza Taghizade; Zahra Tizmagh; Ali Vaezzade


Skin Dosimetry of Some Beta Sources using the VARSKIN2 Code

Volume 6, Issue 3,4, November and December 2009, Pages 73-81

Ali Asghar Mowlavi; Azam Sadat Afzali


Monte Carlo Simulation of a Linear Accelerator and Electron Beam Parameters Used in Radiotherapy

Volume 6, Issue 2, May and June 2009, Pages 11-18

Mohammad Taghi Bahreyni Toossi; Mehdi Momen Nezhad; Seyed Mohammad Hashemi


Optimization of Beam Orientation and Weight in Radiotherapy Treatment Planning using a Genetic Algorithm

Volume 6, Issue 2, May and June 2009, Pages 51-58

Reza Faghihi; Mohammad Amin Mosleh-Shirazi; Fatemeh Moradi-Mocarram


Evaluation of MRI-based Polymer Gel Dosimetry for Measurement of CT Dose Index (CTDI) on 64 slices CT Scanners

Volume 6, Issue 2, May and June 2009, Pages 59-70

Leaila Karimi-Afshar; Nader Riahi Alam; Mohammadreza Ay; Mahmoud Allahverdi; Tayeb Alahverdi purfallah; Hassan Hashemi; Ahmad Farahani; Behrooz Reafie; Morteza Bakhteiari


Dosimetric Comparison of Various Radiotherapeutic Treatment Plans Using Cobalt-60 and Linac for Prostate Cancer

Volume 6, Issue 2, May and June 2009, Pages 71-79

Seyed Ali Vaezzadeh; Mahmood Allahverdi; Hasan Nedaie; Mahdi Aghili; Mahbod Esfehani; Ehsan Mohammadi


Evaluation of Patients’ Exposure during Angiography and Angioplasty Procedures in the Angiography Department of Shahid Madani Hospital in Tabriz

Volume 6, Issue 1, March and April 2009, Pages 53-59

Asghar Mesbahi; Naser Aslanabadi; Parinaz Mehnati; Ahmad Keshtkar


The Influence of Crystal Size and Material on Intercrystal Scattering and Parallax in PET Block Detectors: A Monte Carlo Study

Volume 5, Issue 3,4, November and December 2008, Pages 67-76

Sara Lashkari; Saeed Sarkar; Mohammadreza Ay; Arman Rahmim


Determination of Dosimetric Parameters of the Second Model of Pd-103 Seed Manufactured at Agricultural, Medical and Industrial Research School

Volume 5, Issue 1,2, May and June 2008, Pages 9-22

Gholamreza Raisali; Mahdi Sadeghi; Vahideh Ataeinia; Arjang Shahvar; Maryam Ghasemi Ghonchehnazi


Investigation of the Field Size Effect on Wedge Field Isodose Curves Angle for Two Energies; 6 & 18 MV, produced by VARIAN 2100C Linac

Volume 5, Issue 1,2, May and June 2008, Pages 35-43

Mohammad Javad T ahmasebi; Mohammad Ali Behrooz; Shole Arvandi; Davood khezerloo; Mojtaba karbalai


The Measurement of Low Frequency Magnetic Field of Two Kinds of GSM900 Mobile Phone

Volume 5, Issue 1,2, May and June 2008, Pages 43-53

Mehri Kaviani Moghadam; , Seyed Mohammad Jafar Pourmir Firoozabadi; M. Lak; M. Janahmadi


Monte Carlo Dose Calculation of 90 Sr/ 90 Y Source in Water Phantom

Volume 5, Issue 1,2, May and June 2008, Pages 67-72

Ali Asghar Mowlavi


Fabrication of Free Air Well Type Ionization Chamber and Calculational Assessment and Measurement of Its Operational Characteristics

Volume 4, Issue 3,4, November and December 2007, Pages 1-10

Koroush Arbabi; Gholamreza Raisali; Masoomeh Dehghani Moghadam; Mostafa Ghafoori; Arjang Shahvar; Said Hamidi


Comparison of the Obtained Results from Two Calibration Methods in MRI Brachytherapy Normoxic Polymer Gel Dosimetry

Volume 3, Issue 1, March and April 2006, Pages 11-22

M. Sedaghat; M.H Zahmatkesh; R. Jaberi; Sh. Akhalghpoor; M. Allahverdi


Evaluation of the Effects of Different Filters and Helium Bag on the Reduction of Electron Contamination in Photon Beam of Neptun Linac

Volume 2, Issue 3, September and October 2005, Pages 9-20

M. T. Bahreyni Toosi; H. Saberi; M. Momen Nezhad


An assessment of the Doses Received by Children from CT Examinations Along with the QC Parameters from a Conventional CT System

Volume 2, Issue 3, September and October 2005, Pages 31-44

T. Sadeghyani; B. Hashemi Malayeri; H. Hashemi; A.A. Sharafi


New formula for Calculation of Cobalt-60 Percent Depth Dose

Volume 2, Issue 3, September and October 2005, Pages 53-60

M. J. Tahmasebi Birgani; M. Ghorbani


Verification of the Accuracy of the Delivered Dose in Brain Tumors by in Vivo Dosimetry Using Diode Detectors

Volume 2, Issue 2, May and June 2005, Pages 13-25

M. Taghizadeh Dabbagh; M. Allahverdi; M. Esfahani; P. Haddad